Powering down hot runner energy with Gunther BlueFlow

GÜNTHER has recently worked with a UK plastics manufacturer to test its BlueFlow hot runner system, which brought a 24.6% reduction in energy consumption compared to an existing tool.

Powering down hot runner energy with Gunther BlueFlow
Published: | 2 min read

GÜNTHER has recently worked with a UK plastics manufacturer to test its BlueFlow hot runner system, which brought a 24.6% reduction in energy consumption compared to an existing tool.


gunther

A UK-based plastics manufacturer has recorded a 24.6% reduction in energy consumption after fitting a GÜNTHER BlueFlow hot runner system to one of its moulds, in a like-for-like comparison against an existing tool using a competitor’s hot runner system. 

The manufacturer fitted a four-drop valve-gate BlueFlow system to a mould with the same footprint as an existing tool that was fitted with a competitor’s hot runner system. 

Both tools were used to produce identical PP caps, with a wall thickness of approximately 1.6mm and a part volume of 9.46 cm³, at cycle times of 14.8 seconds. To control for other variables, both tools ran on the same injection moulding machines and used independent temperature controllers from the same third-party manufacturer. 

Barrel temperatures on both tools were set between 210 °C and 225 °C, with hot runner temperatures set to 210°C. Each temperature controller was fitted with an energy monitor. 

Over a one-hour measurement period, the competitor’s system used 764Wh, compared with 576Wh for the GÜNTHER BlueFlow system.

The BlueFlow system uses GÜNTHER’s thick-film heater technology and a bi-metallic titanium shaft design, which the company says provides a more even temperature profile and reduces heat loss between the hot runner and the mould tool. GÜNTHER also states that the design supports leak-free operation.

GÜNTHER’s own figures put typical energy savings for its nozzles at up to 50% in isolation. In this case, engineers at the moulding company wanted to measure total system energy consumption, including manifold consumption, under real-world production conditions.

“We wanted to see if the energy savings from the GÜNTHER BlueFlow nozzles stacked up against the other tools we were using with a different hot runner supplier, and the tests confirmed a 24.6% reduction in total hot runner energy consumption,” said the Injection Moulding Chief of Development. “This was our first time using a GÜNTHER system, and we’ve found the valve gate design straightforward to maintain.”

A brief training session was provided to the manufacturer’s in-house toolroom team, who noted the sealing of the shaft in the mould inserts and the process for replacing worn gates by exchanging PM inserts.

The results add to a small but growing body of comparative data on hot runner energy consumption, as moulders increasingly assess supplier options against measured performance on the shop floor, alongside manufacturer specifications.

About the author

Giulia Daniele

Giulia Daniele

Head of Content across Plastics IQ, BP&R and Interplas, Giulia has been writing for the publication since 2024, becoming a recognised voice in the industry.

All articles

Sign up to our newsletter

The week's biggest stories from this industry, direct to your inbox.

Personal information

More in Ancillary Equipment

See all

More from Giulia Daniele

See all

From our partners

Formulating the future

Formulating the future

BP&R sat down with the Rapid Colour Services team to discuss the company’s new UEE Useon extrusion line, its practical benefits and what this investment means for the business’s future.

/